650 research outputs found

    3PAC: Enforcing Access Policies for Web Services

    Get PDF
    Web services fail to deliver on the promise of ubiquitous deployment and seamless interoperability due to the lack of a uniform, standards-based approach to all aspects of security. In particular, the enforcement of access policies in a service oriented architecture is not addressed adequately. We present a novel approach to the distribution and enforcement of credentials-based access policies for Web services (3PAC) which scales well and can be implemented in existing deployments

    Single-mode delay time statistics for scattering by a chaotic cavity

    Get PDF
    We investigate the low-frequency dynamics for transmission or reflection of a wave by a cavity with chaotic scattering. We compute the probability distribution of the phase derivative phi'=d phi/d omega of the scattered wave amplitude, known as the single-mode delay time. In the case of a cavity connected to two single-mode waveguides we find a marked distinction between detection in transmission and in reflection: The distribution P(phi') vanishes for negative phi' in the first case but not in the second case.Comment: 10 pages including 3 figures; to be published in Physica Scripta (proceedings Nobel Symposium on Quantum Chaos

    Fixed-Node Monte Carlo Calculations for the 1d Kondo Lattice Model

    Get PDF
    The effectiveness of the recently developed Fixed-Node Quantum Monte Carlo method for lattice fermions, developed by van Leeuwen and co-workers, is tested by applying it to the 1D Kondo lattice, an example of a one-dimensional model with a sign problem. The principles of this method and its implementation for the Kondo Lattice Model are discussed in detail. We compare the fixed-node upper bound for the ground state energy at half filling with exact-diagonalization results from the literature, and determine several spin correlation functions. Our `best estimates' for the ground state correlation functions do not depend sensitively on the input trial wave function of the fixed-node projection, and are reasonably close to the exact values. We also calculate the spin gap of the model with the Fixed-Node Monte Carlo method. For this it is necessary to use a many-Slater-determinant trial state. The lowest-energy spin excitation is a running spin soliton with wave number pi, in agreement with earlier calculations.Comment: 19 pages, revtex, contribution to Festschrift for Hans van Leeuwe

    Mid-frequency aperture arrays: the future of radio astronomy

    Full text link
    Aperture array (AA) technology is at the forefront of new developments and discoveries in radio astronomy. Currently LOFAR is successfully demonstrating the capabilities of dense and sparse AA's at low frequencies. For the mid-frequencies, from 450 to 1450MHz, AA's still have to prove their scientific value with respect to the existing dish technology. Their large field-of-view and high flexibility puts them in an excellent position to do so. The Aperture Array Verification Program is dedicated to demonstrate the feasibility of AA's for science in general and SKA in particular. For the mid-frequency range this has lead to the development of EMBRACE, which has already demonstrated the enormous flexibility of AA systems by observing HI and a pulsar simultaneously. It also serves as a testbed to demonstrate the technological reliability and stability of AA's. The next step will put AA technology at a level where it can be used for cutting-edge science. In this paper we discuss the developments to move AA technology from an engineering activity to a fully science capable instrument. We present current results from EMBRACE, ongoing tests of the system, and plans for EMMA, the next step in mid-frequency AA technology.Comment: 8 pages, 7 figures, proceedings of Resolving The Sky - Radio Astronomy: Past, Present and Future (RTS2012), April 17-20, 2012, Manchester, U

    Proof for an upper bound in fixed-node Monte Carlo for lattice fermions

    Get PDF
    We justify a recently proposed prescription for performing Green Function Monte Carlo calculations on systems of lattice fermions, by which one is able to avoid the sign problem. We generalize the prescription such that it can also be used for problems with hopping terms of different signs. We prove that the effective Hamiltonian, used in this method, leads to an upper bound for the ground-state energy of the real Hamiltonian, and we illustrate the effectiveness of the method on small systems.Comment: 14 pages in revtex v3.0, no figure

    Green Function Monte Carlo with Stochastic Reconfiguration

    Full text link
    A new method for the stabilization of the sign problem in the Green Function Monte Carlo technique is proposed. The method is devised for real lattice Hamiltonians and is based on an iterative ''stochastic reconfiguration'' scheme which introduces some bias but allows a stable simulation with constant sign. The systematic reduction of this bias is in principle possible. The method is applied to the frustrated J1-J2 Heisenberg model, and tested against exact diagonalization data. Evidence of a finite spin gap for J2/J1 >~ 0.4 is found in the thermodynamic limit.Comment: 13 pages, RevTeX + 3 encapsulated postscript figure

    Hook plate fixation of acute displaced lateral clavicle fractures: mid-term results and a brief literature overview

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The clavicle hook plate achieves like most other operative techniques, a high percentage of union and a low percentage of complications however concerns about long term complications still exist, particularly the involvement of the acromioclavicular joint.</p> <p>Methods</p> <p>To evaluate the results and long term effects in use of this plate we performed a retrospective analysis with a mean follow up of 65 months (5.4 years) of 28 consecutive patients with acute displaced lateral clavicle fractures, treated with the clavicle hook plate.</p> <p>Results</p> <p>Short term functional results in all patients were good to excellent. All but one patient had a united fracture (96%). Nine patients (32%) developed impingement symptoms and in 7 patients (25%) subacromial osteolysis was found. These findings resolved after plate removal. Twenty-four patients were re-evaluated at a mean follow-up period of 5.4 years. The Constant-Murley score was 97 and the DASH score was 3.5. Four patients (14%) developed acromioclavicular joint arthrosis of which one was symptomatic. Three patients (11%) had extra articular ossifications of which one was symptomatic. There was no relation between the impingement symptoms, subacromial osteolysis and development of acromioclavicular joint arthrosis or extra articular ossifications.</p> <p>Conclusions</p> <p>The clavicle hook plate is a good primary treatment option for the acute displaced lateral clavicle fracture with few complications. At mid term the results are excellent and no long term complications can be addressed to the use of the plate.</p

    Spitzer Observations of 3C Quasars and Radio Galaxies: Mid-Infrared Properties of Powerful Radio Sources

    Get PDF
    We have measured mid-infrared radiation from an orientation-unbiased sample of 3CRR galaxies and quasars at redshifts 0.4 < z < 1.2 with the IRS and MIPS instruments on the Spitzer Space Telescope. Powerful emission (L_24micron > 10^22.4 W/Hz/sr) was detected from all but one of the sources. We fit the Spitzer data as well as other measurements from the literature with synchrotron and dust components. The IRS data provide powerful constraints on the fits. At 15 microns, quasars are typically four times brighter than radio galaxies with the same isotropic radio power. Based on our fits, half of this difference can be attributed to the presence of non-thermal emission in the quasars but not the radio galaxies. The other half is consistent with dust absorption in the radio galaxies but not the quasars. Fitted optical depths are anti-correlated with core dominance, from which we infer an equatorial distribution of dust around the central engine. The median optical depth at 9.7 microns for objects with core-dominance factor R > 10^-2 is approximately 0.4; for objects with R < 10^-2, it is 1.1. We have thus addressed a long-standing question in the unification of FR II quasars and galaxies: quasars are more luminous in the mid-infrared than galaxies because of a combination of Doppler-boosted synchrotron emission in quasars and extinction in galaxies, both orientation-dependent effects.Comment: 42 pages, 14 figures plus two landscape tables. Accepted for publication in Ap

    Compliance of general practitioners with a guideline-based decision support system for ordering blood tests

    Get PDF
    BACKGROUND: Guidelines are viewed as a mechanism for disseminating a rapidly increasing body of knowledge. We determined the compliance of Dutch general practitioners with the recommendations for blood test ordering as defined in the guidelines of the Dutch College of General Practitioners. METHODS: We performed an audit of guideline compliance over a 12-month period (March 1996 through February 1997). In an observational study, a guideline-based decision support system for blood test ordering, BloodLink, was integrated with the electronic patient records of 31 general practitioners practicing in 23 practices (16 solo). BloodLink followed the guidelines of the Dutch College of General Practitioners. We determined compliance by comparing the recommendations for test ordering with the test(s) actually ordered. Compliance was expressed as the percentage of order forms that followed the recommendations for test ordering. RESULTS: Of 12 668 orders generated, 9091 (71%) used the decision-support software rather than the paper order forms. Twelve indications accounted for >80% of the 7346 order forms that selected a testing indication in BloodLink. The most frequently used indication for test ordering was "vague complaints" (2209 order forms; 30.1%). Of the 7346 order forms, 39% were compliant. The most frequent type of noncompliance was the addition of tests. Six of the 12 tests most frequently added to the order forms were supported by revisions of guidelines that occurred within 3 years after the intervention period. CONCLUSIONS: In general practice, noncompliance with guidelines is predominantly caused by adding tests. We conclude that noncompliance with a guideline seems to be partly caused by practitioners applying new medical insight before it is incorporated in a revision of that guideline

    Review of "Biomedical Informatics; Computer Applications in Health Care and Biomedicine" by Edward H. Shortliffe and James J. Cimino

    Get PDF
    This article is an invited review of the third edition of "Biomedical Informatics; Computer Applications in Health Care and Biomedicine", one of thirty-six volumes in Springer's 'Health Informatics Series', edited by E. Shortliffe and J. Cimino. This book spans most of the current methods and issues in health informatics, ranging through subjects as varied as data acquisition and storage, standards, natural language processing, imaging, electronic health records, decision support, teaching methods and ethics. The book is aimed at 'healthcare professionals', and is certainly appropriate for the non-technical informatics user. However, this book is also excellent background reading for the technical engineer who may be interested in the possible problems that confront the users in this field
    • …
    corecore